Categories
Home  > PC Parts  > Networking  > Switches > TP-Link Omada 24-Port Gigabit Stackable L3 Managed PoE+ Switch with 4 10G Slots (SG6428XHP)

TP-Link Omada 24-Port Gigabit Stackable L3 Managed PoE+ Switch with 4 10G Slots (SG6428XHP)

TP-Link Omada 24-Port Gigabit Stackable L3 Managed PoE+ Switch with 4 10G Slots (SG6428XHP)
  • Switches-TP-Link-Omada-24-Port-Gigabit-Stackable-L3-Managed-PoE-Switch-with-4-10G-Slots-SG6428XHP-5
  • Switches-TP-Link-Omada-24-Port-Gigabit-Stackable-L3-Managed-PoE-Switch-with-4-10G-Slots-SG6428XHP-2
  • Switches-TP-Link-Omada-24-Port-Gigabit-Stackable-L3-Managed-PoE-Switch-with-4-10G-Slots-SG6428XHP-3
$2,799.0
or 4x fortnightly payments of $330 with ZipPay
Learn more
- +
Want to be notified when this item is back in stock?

Please enter a valid email address

By clicking 'Notify Me', you agree to our Terms & Conditions and to receive email updates and exclusive promotions, which you may unsubscribe from any time.

WishAdd to Wishlist

Buy Now, Pay Later:  
Buy now with PayPal  
   Click & Collect   Question Mark

Your store is set to:

Loading... Contact Store

   Monday Dispatch   Question Mark

Order within 43hrs and 56mins

Question Mark

Bell  Stock Levels May Vary

Make sure to have the correct store selected. Stock levels are different at every store!
We don't do walk-ins, please make sure to order online for Pickup.

Specifications

  • Product Name:
    TP-Link Omada 24-Port Gigabit Stackable L3 Managed PoE+ Switch with 4 10G Slots (SG6428XHP)
  • Model Number:
    SG6428XHP
  • Brand:
  • Warranty Period:
    5 Year

Description

Switches-TP-Link-Omada-24-Port-Gigabit-Stackable-L3-Managed-PoE-Switch-with-4-10G-Slots-SG6428XHP-1




SPECIFICATIONS:

HARDWARE FEATURES


Interface            

• 24× 10/100/1000 Mbps PoE+ RJ45 Ports

• 4× 10G SFP+ Slots        

• 2× USB 2.0 Ports           

• 1× RJ45 Console Port  

• 1× USB Type-C Console Port    

• 1× RJ45 Management Port       

Fan Quantity     

Four Field-replaceable and Hot-swappable Fans

Power Supply   

Two Field-replaceable and Hot-swappable Power Supply Modules** (100–240 VAC, 50/60 Hz)

               

**Shipping with one PSM500-AC module by default, and another field-replaceable redundant power supply requires purchasing separately.

PoE Ports (RJ45)

• Standard: 802.3at/af compliant

• PoE+ Ports: 24 Ports, up to 30 W per port          

• PoE Power Budget: up to 720 W*          

*The total PoE budget varies with the power supply modules.     

Dimensions ( W x D x H )             

17.3 × 16.5 × 1.7 in (440 × 420 × 44 mm)

Mounting           

Rackmountable

Max Power Consumption           

• 42.9 W (110 V/60 Hz) (With no PD connected)

• 916.6 W (110 V/60 Hz) (With 720 W PD connected and powered by 2× PSM500-AC)        

Max Heat Dissipation   

• 146.29 BTU/hr (110 V/60 Hz) (With no PD connected)

• 3,125.61 BTU/hr (110 V/60 Hz) (With 720W PD connected and powered by 2× PSM500-AC)     

PERFORMANCE


Switching Capacity         

128 Gbps per Unit

Stacking              

• Stacking Number: 8 in standalone mode, 4 in Omada controller mode

• Stacking Port: 10G SFP+ Slot (all uplink ports can be used as stacking ports)       

• Stack Bandwidth: 20 Gbps Per Port (Full-Duplex)            

Packet Forwarding Rate

95.2 Mpps

MAC Address Table        

32 K

Packet Buffer Memory 

3 MB

Jumbo Frame   

9 KB

SOFTWARE FEATURES


Quality of Service           

• Class of Service

- 8 Queues of Priority     

- Port Priority    

- IEEE 802.1p Priority     

- DSCP Priority  

- Queue Min-Bandwidth

- Schedule Mode (SP, WRR, SP+WRR)

• Bandwidth Control      

- Rate Limit         

- Storm Control

• Voice VLAN    

• User-Defined OUI        

• Smoother Performance             

• Action for Flows           

- QoS remark (802.1P Remark, DSCP Remark)     

L3 Features       

• IP Interfaces:

- IPv4: Max 256, IPv6: Max 256 

• Static Routing

- Max 1,024, IPv6: Max 512        

• Host Route Table: Max 6,100 entries

• RIP: Version v1/v2, Max 8,190

• OSPF: Version v2/v3; v2: Max 8,190, v3: Max 4,097      

• VRRP: Version v2/v3, Max 64 groups

• ECMP: 256 entries, max 32 ECMP Nexthops per Destination      

• Static ARP: 512 static entries   

• Dynamic ARP: 7,680 dynamic entries

• Proxy ARP       

• DHCP Server: 

- Max 8K IP Pools             

- Max 1,000 Manual Binding Entries

• DHCP Relay:   

- Relayed Interface          

- Relayed VLAN

L2 and L2+ Features      

• Link Aggregation

• Spanning Tree Protocol             

• Port-based and VLAN-based Loopback Detection           

• 802.3x Flow Control   

• Supports 2,048 IGMP groups  

• ERPS 

• Mirroring        

• RSPAN              

• MAC Address Table     

• PIM-DM (IPv4)             

• Multicast         

- IGMP Snooping             

- MLD Snooping

- L2 Multicast Table         

- Fast Leave        

- Multicast VLAN Registration (MVR)

- Static Multicast IP         

- Multicast Filtering         

Advanced Features        

• Automatic Device Discovery

• Batch Configuration 

• Batch Firmware Upgrading    

• Intelligent Network Monitoring

• Abnormal Event Warnings     

• Unified Configuration              

• Reboot Schedule        

               

These functions require the use of the Omada SDN Controller.

 

ISP Features:     

• 802.3ah Ethernet Link OAM    

• L2PT (Layer 2 Protocol Tunneling)

• Device Link Detect Protocol (DLDP)

• DDM 

• sFlow

VLAN    

• Max 4K VLAN Group (802.1q VLAN)

• 802.1Q Tagged VLAN 

• MAC VLAN Entries: 200             

• Multicast VLAN             

• Management VLAN    

• VLAN VPN (QinQ): Max 256 entries

• GVRP

• Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries               

• VLAN VPN      

• Voice VLAN    

• Private VLAN 

Security              

• Port Isolation

• CPU-Defend   

• ARP Inspection (Dynamic ARP Inspection)         

• DoS Defend    

• IP-MAC-Port Binding  

-1,024 Entries   

- DHCP Snooping             

- ARP Inspection              

- IPv4 Source Guard        

• IPv6-MAC       

-Port Binding     

-1,024 Entries   

- DHCPv6 Snooping        

- ND Detection  

- ND Snooping  

- IPv6 Source Guard        

• DHCP Filter     

• Static/Dynamic Port Security   

- Up to 64 MAC addresses per port

• Broadcast/Multicast/Unknown-unicast Storm Control 

- kbps/ratio control mode            

• 802.1X             

- Port base authentication           

- Mac base authentication           

- VLAN Assignment         

- MAB  

- Guest VLAN    

- RADIUS authentication and accountability support         

• AAA (including TACACS+)          

• Secure web management through HTTPS with SSLv3/TLS 1.2    

• Secure Command Line Interface (CLI) management with SSHv2

• IP/Port/MAC-based access control

MANAGEMENT


Omada App       

Yes. Requiring the use of the Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.

Centralized Management           

• Omada Cloud-Based Controller

• Omada Hardware Controller   

• Omada Software Controller     

Cloud Access     

Yes. Requiring the use of the Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller.

Zero-Touch Provisioning              

Yes. Requiring the use of the Omada Cloud-Based Controller.

Management Features 

• Web-based GUI

• Command Line Interface (CLI) through console port, telnet        

• SNMPv1/v2c/v3          

- Trap/Inform    

- RMON (1, 2, 3, 9 groups)           

• SDM Template               

• DHCP/BOOTP Client    

• 802.1ab LLDP/LLDP-MED          

• DHCP Auto Install        

• Dual Image, Dual Configuration

• CPU Monitoring           

• Cable Diagnostics         

• Password Recovery     

• SNTP 

• System Log     

• EEE    

OTHERS


Package Contents           

• SG6428XHP Switch

• Power Cord    

• RJ45 Console Cable     

• Quick Installation Guide            

• Rackmount Kit              

• Rubber Feet   

System Requirements  

Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.

Environment    

• Operating Temperature: 0–45 ℃ (32–113 ℉);

• Storage Temperature: -40–70 ℃ (-40–158 ℉) 

• Operating Humidity: 10–90% RH non-condensing         

• Storage Humidity: 5–90% RH non-condensing

Notes

Zero-Touch Provisioning requires the use of the Omada Cloud-Based Controller. Please go to www.tp-link.com/en/omada-cloud-based-controller/product-list/ to confirm which models are compatible with the Omada Cloud-Based Controller.

*The total PoE budget varies with the power supply modules.

**Ships with one PSM500-AC module by default, and another field-replaceable redundant power supply requires a separate purchase.

 


Reviews

Reviews

Reviews
Write Review

Similar Products